TR-5 serija kompaktnih vodoodpornih dataloggerjev

TR-51 TR-52
RTR-51/51A RTR-51L/51AL
-40 do 80°C -60 do 155°C,
TR-50U TR-57U
RTR-51/51A RTR-51L/51AL
USB čitalec                  prenosni čitalec
260.000 točk spomina
100 ur delovanja

Funkcionalnost

Testirani, izpolnjujejo zahtevi RTCA DO-160E, Section 21 (Radio Technical Commission for Aeronautics). Naprava je testirana in ne povzroča motnje delovanja med poletom. (www.rtca.org). Opremljen z LCD display-em, ki prikazuje temperaturno stanje, stanje preseženih vrednosti, stanje baterije in delovanje. Merilnik ima 16.000 točk spomina z nastavitvijo intervala beleženja od 1 sekunde do 1 ure. Življenska doba baterije je 4 leta.

RVR-52AL

  TR-51S TR-52S
Measurement Item Temperature Temperature
Measurement Channels 1 Ch (Internal Sensor Type) 1 Ch (External Sensor type)
Measurement Range -40 to 80°C -60 to 155°C
Measurement Accuracy Typ. ±0.5°C Typ. ±0.3°C : -20 to 80°C
Typ. ±0.5°C: -40 to -20°C
80 to 110°C
Typ. ±1.0°C : -60 to -40°C
110 to 155°C
Measurement Display Resolution 0.1°C
Recording Capacity 16000 data
Recording Start Method Immediate / Programmed
Recording Mord Endless / One-time
Recording Interval Select from 1,2,5,10,15,20 and 30 seconds
or from1,2,5,10,15,20,30 and 60 minutes
LCD Display Items Temperature measured, recording conditions, battery life warning,
memory FULL, sensor unconnected, over measurement range,
temperature unit (°F / °C) and Upper / Lower limit over
Power (*1) Lithium battery ER3V M x 1 (Lithium battery CR2 also okay)
Battery Life (*2) Maximum 4 years
Waterproof Capacity IP67 (Immersion proof) IP64 (Splash resistant)
External Dimensions H62mm x W47mm x D19mm (Excluding protrusions)
Weight Approx. 54g including battery Approx. 55g including battery
Unit Temp. Resistance -40 to 80°C
Standard Sensor Built - in TR-5106: Teflon resin sensor
Accessories Included Lithium Battery ER3V M x 1, Tube x 1, Strap x 1,
User's Manual (Warranty) x 1
  • (*1) The lithium battery (ER3V M) is not sold in stores. It can be purchased through our distributors as (Optional Battery Set TR-10P2) Normal lithium batteries sold in stores (CR2) can be used, but the operating range is reduced to -20°C to 60°C.If you will be using the logger in an environment where temperatures may be lower than -20°C or higher than 60°C, we strongly suggest purchasing and using the “Optional Battery Set TR-10P2”.
  • (*2)Battery life depends upon the measuring environment, recording interval, and quality of the battery being used.

 

  TR-50U
Compatible Models TR-51S / 52S, TR-51A / TR-52
PC Interface USB Communication: USB 1.1 (with PC)
Communication Speed TR-51S /52S:
MAX speed 19200bps / Download Time at Full Data: about 20 seconds
TR-51A / 52 :
MAX speed 2400bps / Download Time at Full Data: about 160 seconds
Dimensions H: 80mm x W: 56mm x D: 16.5mm (excluding protrusions)
Weight Approx. 30g
Operating Environment Temperature: -10 to 60°C
Humidity: less than 90%RH (No condensation)
Do not use if the Data Logger is wet.
* Communication is not possible with RTR-5 Series units.

 

  TR-57U
Compatible Models TR-51A, TR-52, TR-51, TR-51S, TR-52S, TR-71U, TR-72U
Recording Capacity 256,000 data readings
16 units of TR-71U at full data (16,000 readings x 16)
Collect and manage data from up to 250 separate collections.
Functions Downloading Data (possible to display results of upper and lower limit check after downloading)*
Display Saved Data Graphs, Set Recording Start for Remote Data Loggers,
Display Saved Data Highest and Lowest measurement values
LCD Display Contrast Adjustment, Backlight Function
Power Two AAA Alkaline Batteries (LR03), Can use rechargeable AAA Ni-Cd or Ni-MH 1.2V batteries
Battery Life Used 30 minutes daily is about 160 days
Used 1 hour daily is about 100 days
Used 2 hours daily is about 50 days
Data Backup For about 5 days from the time of battery removal
(If a working battery has been in the unit for more than twenty-four hours)
For about 1 year with batteries in use
(If all battery power is lost the stored data will be lost)
PC Communication Interface USB / RS-232C: 19200bps
Data Logger Communication Interface RS-232C Communication (Speed : 9600bps)
Optical Communication (Speed : 2400bps)
Interface Communication Time Data from TR-57U to Computer :
One Full Logger's Data:USB 5 sec./RS-232C 25 sec.
Data from TR-7U Series to TR-57U via cable :
One Full Logger's Data:50 sec
Data from TR-7U Series to TR-57U via cable :
One Full Logger's Data:50 sec
Dimensions H125mmx W58mm x D23.8mm (excluding protruding part)
Weight Approx. 115g (Including 2 AAA Alkaline batteries)
Operating Environment Temperature : 0°C to 50°C
Humidity : Less than 90%RH
(Without dew condensation)

 

Več info na 041 612 309 ali info (at) haccpnow.si